Product Details - RALGRO® SUPER IMPLANTS
Reg. No. G1407 (Act 36/1947)
Indications:
High‑dose hormone‑free growth stimulant for improved body mass gain and feed conversion in cattle of any age and any sex in feedlots and on good grazing plus supplement. It improves the beef fat ratio in the carcass by reducing fat deposition.
Storage instructions:
Store in a cool place.
Composition:
Each pellet contains: Zeranol 12 mg (73,8 % m/m)
Each implant contains: Zeranol 72 mg (6 pellets)
Warnings:
- Do not use implant area for human or animal consumption. No withdrawal period for meat.
- DO NOT USE IN BREEDING ANIMALS. Use for slaughter animals only.
- IMPLANT PELLETS ON THE BACK OF THE EAR ONLY.
- Increased incidence of vaginal prolapse may occur in treated animals.
- Avoid crushing of pellets.
- Keep out of reach of uninformed persons, children and animals.
- Although this product has been extensively tested under a large variety of conditions, failure thereof may ensue as a result of a wide range of reasons. If this is suspected, seek veterinary advice and notify the registration holder
DIRECTIONS FOR USE: USE ONLY AS DIRECTED
Dosage
- Cattle: 72 mg (1 implant i.e. 6 pellets)
Administration via the RALOGUN®
- Insert the cartridge (with the large hollow axle facing to the back i.e. toward the pistol grip) until it snaps into place.
- Always use a sharp needle. A blunt needle tears tissue and makes proper implanting difficult.
- Wipe the intended puncture site on the back side of the ear with a piece of cotton or gauze moistened with rubbing alcohol
- Insert the needle of the RALOGUN under the loose skin and above the cartilage on the back side of the ear as shown. After the needle has been inserted its full length under the skin the point of the needle should reach into the pocket under the loose skin near the base of the ear. In this area you can pick up the skin with your fingertips.
- N.B. Avoid damage to blood vessels and cartilage.
- Squeeze the trigger of the RALOGUN to deliver the full dose of RALGRO. Keep the trigger depressed while withdrawing the needle to be sure that the RALGRO implant remains in position.
- Wipe the needle with cotton or gauze moistened with alcohol or other suitable disinfectant. Do not dip the needle in solution ‑ it could clog the needle.
- Rotate cartridge in direction indicated by the arrow until a new dose is visible and centred in window.
- The RALOGUN is now ready for next implantation.
Registration holder:
Cooper Veterinary Products (Pty) Ltd
Co. Reg. No. 2002/021376/07